EasyManua.ls Logo

Argo S - Page 351

Argo S
438 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Ontario Drive & Gear Limited www.odg.com
PH.(519)- 662-2840 FAX (519)- 662-2421
Transmission Argo Service Manual
TR-12
11. Thread (2) 5/16"x18 bolts into the threaded boss at both locations on the Side
Cover. As the bolts come in to contact with the Housing below, the Cover is pulled
from the Output Shaft. Thread the bolts a little at time alternating between the two.
This will ensure that it does not bind during separation. Photo TR-19
Make sure that the bolts threaded into the Cover are long enough to guarantee that the
Cover will completely separate itself from the Housing and may be easily lifted off by
hand. In most cases, with this type of separation, the differential will remain within the
Housing. Photo TR-20 Remove the differential from the Housing as described in step 8.
TR-17 TR-18
TR-19
TR-20
Separating the Side Cover on Transmissions Manufactured From Serial Numbers:
25631GU,
25668HU
25700MU
9. These Side Covers utilize a threaded boss in 2 locations. Photo TR-17
10. Remove the Retaining Ring and Shim on the Output Shaft side of the Cover, Photo
TR-18, and ensure that the reverse idler dowel pin has been freed of the cover as in
step 3 & 4

Table of Contents

Related product manuals