Z100-TYPE HARDWARE
Installation—Non-FCC Registered Recorded Announcement Equipment
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
11.
12.
13.
Determine port assignment of feature from Announcement Form:
EXAMPLE: Port Number B
02
01
Carrier
Slot Circuit
Run and connect A25D cable from station side (see Note) of cross-connect field to
25-pair connector on auxiliary cabinet’s ED-1E443-10 Intra-Connection Panel (see
Figure 2-111).
Note: This connection is to a Z203A1 connecting unit provided in a Z100B1
Connector Module. If Z100A1 Connector Modules are used at the cross-
connect field, a connecting unit on the station side must be replaced with a
Z203A1 connecting unit.
Run and connect B25A cable from 25-pair connector on ED-1E443-10 Intra-
Connection Panel to switch side of cross-connect field (see Figure 2-111).
Install yellow (auxiliary) labels on connector modules.
Mount 36A voice coupler.
Remove cover from 36A voice coupler and make connections to 110-type wiring
blocks on ED-1E443-10 Intra-Connection Panel (see Figure 2-111).
Connect output of 2012D transformer to AC and ACG terminals on 36A voice
coupler.
Plug 2012D transformer into 117-volt power outlet not under control of a wall
switch.
Install cover on 36A voice coupler.
Install patch cord at cross-connect field.
Install recorded announcement equipment per manufacturer’s instructions.
Connect 2-pair line cord (modular plug at one end) from information outlet to
recorded announcement equipment (see Figure 2-111).
Administer per AT&T System 75 and System 75 XE Implementation and AT&T
System 75 and System 75 XE Administration.