EasyManua.ls Logo

AT&T 75 - Installing the Cable Access Panels (Caps)

AT&T 75
593 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Z100-TYPE HARDWARE
CONNECTOR MODULE LABEL ORDERING INFORMATION
Description Qty. Per Code
Comcode
101A Labels
102A Labels
103A Labels
104A Labels
105A Labels
106A Labels
107A Labels
108A Labels
109A Labels
110A Labels
111A Labels
112A Labels
113A Labels
114A Labels
115A Labels
116A Labels
117A Labels
118A Labels
119A Labels
120A Labels
121A Labels
122A Labels
123A Labels
60
40
40
40
20
10
10
30
10
60
40
40
40
20
100
100
100
10
10
10
10
40
10
103 969 754
103 969 762
103 969 770
103 969 788
103 969 796
103 969 804
103 969 812
103 969 820
103 969 838
103 969 846
103 969 853
103 969 861
103 969 879
103 969 887
103 985 131
103 985 149
103 985 156
103 985 164
103 985 172
103 985 180
103 985 198
103 985 206
103 985 214
Installing the Cable Access Panels (CAPs)
The cable access panels are wall-mounted. A maximum of three panels can be mounted in a
vertical column. To install the cable access panels, proceed as follows:
1.
2.
3.
4.
5.
6.
7.
8.
9.
Align the first cable access panel 4 inches (10.2 cm) to the left side and 6 inches
(15.2 cm) above the cross-connect field location (see Figure 2-26).
Mark the keyhole mounting screw location in the upper-right corner of the cable
access panel.
Remove the cable access panel, drill a hole in the backboard, and start a 3/4-inch
(19 mm) No. 12 wood screw.
Move the cable access panel back into place and align.
Mark the remaining three keyhole mounting screw locations in the cable access
panel.
Remove panel and drill pilot holes in the backboard.
Move the cable access panel back into place and fasten to the backboard with the
3/4-inch (19 mm) No. 12 wood screws.
Align next cable access panel 1 inch (2.5 cm) below the previously positioned cable
access panel and repeat steps 2 through 7.
If you are installing two columns of cable access panels, position top cable access
panel 4 inches (10.2 cm) to the left of the first column of cable access panels and
repeat procedure from step 2.