Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Install and Cable the Cabinet
1-116Install the BRI terminating resistor
1
Figure 1-58 shows the wiring connections for the 110RA1-12 terminal block. The
TN556 BRI switch port is terminated to bottom row C.
Figure 1-58. Typical installation of terminating resistor block
For point-to-point wiring, the top row connects to the blue station field. The pair
connects from the 110RA1-12 to the standard 4-pair circuit. Pair 1 from the
110RA1-12 connects to Pair 1 of the station field, and Pair 2 connects to Pair 3 of
the station field.
Connect row B (output) to the second terminal common to the multi-point circuit to
accommodate 2 terminal basic multi-point applications.
Figure Notes
1. Part of terminating resistor block
2. White or purple field
3. Part of 4-pair blue field
4. From ISDN T-interface circuit
(2-pair)
5. To ISDN S/T-interface terminals
6. 2-pair cross-connect
7. Basic multi-point option
8. 4-pair horizontal cables
9. Row “A”
10. Row “B”
11. RowC
TT1R R1
term_blk RPY 012098
3
4
5
1
6
6
2
9
11
7
8
10