Upgrade and Repair Procedures
5-3Replacing a TN795 board with a TN2314 for R10
5
Replacing a TN795 board with a TN2314
for R10
This section shows the basic steps to follow when replacing a TN795 circuit board
with a TN2314 circuit board. These steps assume the technician will connect a
laptop directly to the Definity One or IP600.
NOTE:
You still need a crossover cable to connect your laptop directly to the
Definity One or IP600.
NOTE:
The procedure for obtaining and installing a license file has changed. If the
valid license file does not already exist on the system or your laptop, a
license file must be created using Avaya’s new Remote Activation Feature
(RFA). If you are an approved RFA user, you can create and install the
license file. If not, you must attend training and become an approved RFA
user.
License File Remote Feature Activation (RFA) is a Web-based application that
enables the creation and deployment of License Files for all switches beginning
with R10. The License File enables the switch’s software category, release,
features, and capacities. License Files are created using SAP order information
and/or current customer configuration information.
Without a license file, the
switch does not provide normal call processing.
Without a valid license installed or a mismatched license:
1. The system generates a major alarm.
2. Depending upon the nature of the error, a 6-day countdown timer starts,
but call processing continues unchanged.
3. If the countdown timer expires, the switch runs in Administration Mode only,
and the call processing capability is limited to incoming and outgoing calls
only to pre-administered numbers.
NOTE:
With Release 10, the
init
login no longer has the capability to change
the customer options, offer option, or special applications forms.
TN2314 is the processor board that is replacing the TN795 effective as of R10.