Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Hardware Additions
6-18Add CO, FX, WATS, and PCOL
6
Disable Filesystem
To free up resources on the source board, you must delete the files and disable
the filesystem.
1. Type remove file board
UUCSS filename
and press Enter to remove
image files from the source board.
2. Type disable filesystem board
UUCSS
and press Enter to disable the file
system on the source board.
NOTE:
This process is only successful if no files remain on the source board.
Add CO, FX, WATS, and PCOL
Requirements
Each Central Office (CO), Foreign Exchange (FX), Personal Central Office Line
(PCOL), or Wide Area Telecommunications Service (WATS) trunk connects to 1
port of either an 8-port TN747B or to 1 of several CO trunk circuit packs.
Installation
1. Determine the port assignment of the trunk from Trunk Group form.
2. Install a TN747B or a CO Trunk circuit pack in the assigned carrier slot (if
an additional circuit pack is required).
3. Administer the forms listed under CO, FX, WATS, or PCOL Trunk Group in
DEFINITY Enterprise Communications Server Release 10 Administrator’s
Guide (
555-233-506).
EXAMPLE: Port Number 3 A 07 01
Cabinet Carrier Slo
t
Circuit
(Port
Network)
(or Compact
Modular
Cabinet)