December 2001
Install and Cable the Cabinet
1-119Install multi-point adapters
1
Basic multi-point installation distances
Figure 1-61 provides cabling information for fanout of ISDN-BRI multi-point
installations. The terminating resistor is located in the satellite closet. All distances
assume 24 AWG (0.26 mm
2
) D-Inside Wire (DIW).
Figure 1-61. Basic multi-point with one work location
Figure Notes
1. S-interface source (TN556)
2. Terminating resistor
3. Satellite closet
4. Maximum distance from S-interface
source to work location (1600 feet)
(488 m)
5. Maximum distance from satellite
closet to work location (250 feet)
(76 m)
6. System cabinet
7. Terminating endpoint 1
8. Terminating endpoint 2
9. Work location
10. Maximum distance from information
outlet to terminating endpoint
(33 feet) (10 m)
11. Information outlet
2
3
8
9
7
1
10
11
11
5
4
6
inst_dis RPY 012098