Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
System Initialization
3-39Administer DEFINITY for Intuity AUDIX initialization
3
Check Class of Restriction
1. At the SAT or Avaya Site Administration window, type disp cor 1, where 1
is the COR you plan to use for the Intuity AUDIX port stations.
The Class of Restriction form displays:
2. Ensure that the COR has an FRL of 7 to allow for Outcalling and Fax Print.
3. Ensure that Calling Party Restriction is set to none.
4. Ensure that Time of Day Chart is set to 1.
5. Press F7.
Page 2 of the Class of Restriction form displays.
6. Press F7.
Page 3 of the Class of Restriction form displays:
7. Ensure that all fields are set to y so there are no restrictions.
NOTE:
Pay attention to toll fraud issues.
8. Press F1.