Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Miscellaneous Procedures
C-5Installing INTUITY languages other than English
C
Use the following function key sequences when using the W2KTT terminal type:
Installing INTUITY languages other than
English
To access the DEFINITY ONE
TM
or IP600
TM
, the technician needs a laptop, a
PCMCIA card for the laptop, a 451A adapter, a D8W cord, a cross-over cord, and
the CD with the Merrill-Lynch INTUITY AUDIX
TM
R5.0 Announcement set.
A cord, comcode 846943306, can be used. If this cord is unavailable, a 104 block
can be used with 2 D8W cords. Wire the 104 block with the white, orange pair
transposed with white, green pair between the jacks. The 3Com
TM
3CXFE575BT
nic card needed to access the TN2314 is to be left on site all the time in the right
slot. If everything is connected properly and the laptop is up and running, there will
be a green LED lit on the nic plugged into the TN2314. If there is no LED, recheck
the connections.
Verify the CD can be read by the laptop CD-ROM.
Action Key sequence
Refresh Esc r
Cancel Esc x
Submit Esc e
Logout Esc l (lower case L)
Clear field Esc c
Help Esc h
Next form Esc f n
Next page Esc n
Prev page Esc p
Edit vec Esc f 6
Dir page Esc d p
Update form Esc u f
Prev field Esc p
Next field Esc N
Prev Field Esc f p