Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
System Initialization
3-31Administer DEFINITY ONE or IP600
3
Setup Call Detail Recording (CDR)
To ensure the proper collection of CDR/SMDR call records from the DEFINITY
ONE and IP600 PBX when using the Collect from File Protocol, it is necessary to
collect call records via a LAN connection between the DEFINITY ONE/IP600
server platform and the call accounting client platform. Administration of the
network connections is described below.
Before beginning, ensure that proper network connectivity exists between the
DEFINITY ONE or IP600 server platform and the call accounting client platform.
Also, ensure that call rating has been turned off in the call accounting client, if the
database has not yet been initialized.
A login for the Call Accounting system has to be established in the DEFINITY
ONE
TM
or IP600
TM
Windows 2000 Server
TM
software. This is accomplished as
follows, using either Terminal Server
TM
to access the system desktop, or a
customer-supplied keyboard, mouse, and monitor:
1. Select Start, Programs, Administrative Tools (Common).
2. Click on User Manager.
3. On the toolbar, click User, and select
New User
.
4. In the dialog box, assign the
Username
(this is the login) and
Password
.
NOTE:
The
Full Name and Description
are optional. The option check boxes
are the customer’s choice; however, we recommend that
User
Cannot Change Password
and
Password Never Expires
should be
the only ones checked.
5. Click on Groups at the bottom of the dialog box.
6. Make the login a member of
officeadmin
and
Users
groups and click OK.
7. Click OK in the
New User
dialog box.
8. Close
User Manager
.
Sharing CDR Data
The following steps are for sharing the CDR data. This is set up via Terminal
Server
TM
or the PC console to access the system desktop:
1. Right-click on the DefinityOne icon on the desktop.
2. Select
Explore
.
3. Click on the + in front of the D: drive.
4. Click on the + in front of LucentData.
5. Right-click on the CDR folder, and select
Sharing
.