Installation and Upgrades for DEFINITY ONE and
IP600 Internet Protocol Release 10
555-233-109
Issue 6
December 2001
Install and Cable the Cabinet
1-57Install the DEFINITY ONE system cabinet
1
Floor-mount the CMC cabinet
The dimensions of each cabinet (with floor pedestal) are 28.5 inches (72.4 cm)
high, 24.5 inches (62.2 cm) wide, and 12 inches (30.5 cm) deep. Maintain a
service clearance of 12 inches (30.5 cm) on the left, right, and front of the cabinet.
If your configuration requires 2 cabinets, make sure each maintains the service
clearance of 12 inches (30.5 cm) on the left, right, and front sides.
To floor-mount the cabinet:
1. Floor-mount the cabinet as shown in Figure 1-25.
Figure 1-25. Typical floor mount installation
2. Proceed to ‘‘Check AC power and ground for DEFINITY ONE’’ on page
1-64.
Figure Notes
1. Left panel (floor-mount pedestal)
2. #12 x 1-inch shoulder screws
3. 12 inches (30.5 cm) minimum from
nearest object (required to service
the circuit packs)
indmflor KLC 110397
1
2
3