System Initialization
3-19Resolve alarms
3
Windows 2000 Server Alarm Test
1. Access the bash from the lac.
2. At the prompt type wrntevent GAM 0 9991
3. Press <Enter>.
NOTE:
This causes a Major GAM alarm. After the system has called out, at the
bash prompt type cleargamalarm all, and press <Enter> to retire the alarm.
This alarm also causes a Maestro case to be generated that will need to be
closed by the INADS group.
Resolve alarms
To resolve any alarms. Refer to
Maintenance for DEFINITY ONE
Communications System Release 10 (555-233-130) and Maintenance for
Avaya IP600 Internet Protocol Communication Server Release 10
(555-600-100).
Check system status
See ‘‘Avaya (Lucent) access controller bash commands’’ on page G-1 for
information about bash commands that are used in installation and administration.
1. Open a LAC bash shell.
2. To verify system health, execute d1stat and alarmstat.
Place a test call
1. From any telephone connected to a digital line circuit pack, call any nearby
telephone connected to an analog line circuit pack.
2. Verify that the dial tone, ringing pattern, and talk path are acceptable.
3. Place a call through the Central Office (outside call) to any nearby
telephone.
4. Verify that the dial tone, ringing pattern, and talk path are acceptable.