Hardware Additions
6-4Add C-LAN functionality
6
Testing the External Connection to the LAN
To test the external IP connections, ping the C-LAN server and ping a known
computer connected to your network. If everything is configured correctly, the
Result column on the Ping Results screen reads pass. If it reads abort, verify the
IP-address information and check the connectivity, including the cabling.
1. Type ping ip-address
nnn.nnn.nnn.nnn
board
UUCSS
and press Enter.
The variable
nnn.nnn.nnn.nnn
is the IP address of the TN799DP C-LAN
circuit pack and
UUCSS
is the cabinet, carrier, and slot of the TN799DP
C-LAN circuit pack.
2. Type ping ip-address
nnn.nnn.nnn.nnn
board
UUCSS
and press Enter.
The variable
nnn.nnn.nnn.nnn
is the IP address of the customer’s
gateway and
UUCSS
is the cabinet, carrier, and slot of the TN799DP
C-LAN circuit pack.
3. Type ping ip-address
nnn.nnn.nnn.nnn
board
UUCSS
and press Enter.
The variable
nnn.nnn.nnn.nnn
is the IP address of another computer
beyond the gateway and
UUCSS
is the cabinet, carrier, and slot of the
TN799DP C-LAN circuit pack.
The TN799DP C-LAN circuit pack is now installed in the DEFINITY carrier and
connected to the IP network.
ping ip-address 192.168.10.21
PING RESULTS
End-pt IP Port Port Type Result Time(ms) Error Code
192.168.10.21 01A13 CLAN PASS 10 1124