EasyManuals Logo

Azbil VDC User Manual

Azbil VDC
338 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #154 background imageLoading...
Page #154 background image
Operation using the data setting device Azbil Corporation
5-48 Model MTG11A/18A, MTG11B/18B, MTG14C
5-6-7 : Setting specific gravity
This function is used to set the specific gravity when selecting a weight unit (t, kg, g,
lb) in the flow rate range setting.
Set range: 0.1000 to 5.9999
Default: 1.0000
Set the specific gravity in accordance with the following procedure:
Step Procedure Screen
1 Enter ENGINEERING MODE in accordance with
the entry into ENGINEERING MODE (see
section 5-5-10 : on page 5-36). Then press the
or key to display the screen at right.
2 Press the key to move the cursor to the position
under a desired value to be set or changed.
3 Using the or key, change the value to the
desired one to be set.
4 Press the key to move the cursor to the position
under #.
Press the MODE key to return to the
MEASURING MODE and to save data.
m CAUTION
You have only ten minutes to return to MEASURING MODE to save the new value before
the system resets it to the previously saved value.
12.3 %
# GRAVITY
1.0000
12.3 %
# GRAVITY
1.0000
12.3 %
# GRAVITY
1.0050
12.3 %
# GRAVITY
1.0050
CM2-MTG300-2001.book 48 ペー   

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Azbil VDC and is the answer not in the manual?

Azbil VDC Specifications

General IconGeneral
BrandAzbil
ModelVDC
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals