Operation using the data setting device Azbil Corporation
6-34 Model MTG11A/18A, MTG11B/18B, MTG14C
17 RAM FAULT A critical failure. Stop the electromagnetic
flow meter.
The RAM of the converter is abnormal. Turn
OFF the power and then turn it ON again and
check the operation.
If the same message still appears after taking
the action above, contact an Azbil Corp.
representative.
18 ROM FAULT A critical failure. Stop the electromagnetic
flow meter.
The ROM of the converter is abnormal. Turn
OFF the power and then turn it ON again and
check the operation.
If the same message still appears after taking
the action above, contact an Azbil Corp.
representative.
19 SFC FAULT •An SFC error.
Replace the SFC.
20 SPAN OVER ERROR As a result of setting the span, the maximum
measurable flow rate has exceeded 12 m/s.
Check the span, diameter or type of the
detector.
21 >RANGE The calculation result of the SFC has exceeded
the display range.
Restart the SFC.
The SFC battery is running low.
22 : Charge the SFC.
A minor fault.
23 #
Press the key and check the self-
diagnostics result of the SFC.
No.
Error message Checkpoint and action
U
STAT
F/S DIR
CM2-MTG300-2001.book 34 ペー   