170 CONFIGURA TION
13.2.1 Key features of GO TO window
Note. To start a connection configuration session ENABLE GOTO, GETFROM must be set to ENABLED.
Note. To end a connection configuration session ENABLE GOTO, GETFROM must be set to DISABLED.
13.2.2 Key features of GET FRO M window
Note. To start a connection configuration session ENABLE GOTO, GETFROM must be set to ENABLED.
Note. To end a connection configuration session ENABLE GOTO, GETFROM must be set to DISABLED.
PARA METER PRO FILE 3
PRO FL X-A XIS GET FRO M
PRO FL X-A XIS GET FRO M
PIN) Description of function
PARA METER RANGE DEF AULT
PRO FL X-A XIS GET FROM PIN 000 to 720 400
Defines the target source PIN for
connection to PROFL X-A XIS
A default of 400
sho ws that there is
no connection made.
The description of the
target source
connection will scroll
on the bottom line.
The PIN of the target
source connection
will scroll here.
Some functions being
connected are also sho wn
here for extra clarity.
For simple blocks the block
description appears here.
Pressing and holding
the up or dow n key
will cause accelerated
scrolling.
UIPX C ONFIGURATIO N 4
UIP ANALO G GOTO
UIP ANALO G GOTO
PIN) Description of function
PARA METER RANGE DEF AULT
UIP ANALO G GOTO PIN 000 to 720 400
Defines the target destination PIN
for the UIPX analog connection
A default of 400
sho ws that there is
no connection made
The description of the
target connection will
scroll on the bottom
line.
The PIN of the target
connection will scroll
here.
Most blocks being
connected are also sho wn
here for extra clarity.
For simple blocks the block
description appears here.
Pressing and holding
the up or dow n key
will cause accelerated
scrolling.