178 CONFIGURA TION
CONFIGURATION 2
ANALO G OUTPUTS 3
ANALO G OUTPUTS 3
260)S COPE OP SELECT
ANALO G OUTPUTS 3
250)Iarm OP RECTIFY
ANALO G OUTPUTS 3
A OP1 (T1 0) SETUP 4
ANALO G OUTPUTS 3
A OP2 (T1 1) SETUP 4
ANALO G OUTPUTS 3
A OP3 (T1 2) SETUP 4
ANALO G OUTPUTS 3
A OP1 (T1 0) SETUP 4
A OP1 (T1 0) SETUP 4
GET FROM
A OP1 (T1 0) SETUP 4
251)A OP1 DIVIDER
A OP1 (T1 0) SETUP 4
252)A OP1 OFFSET
A OP1 (T1 0) SETUP 4
253)A OP1 RECTIFY EN
13.4 CONFIGURATION / ANALOG
OUTPUTS
PINs used 250 to 260
There are 4 analogue outputs.
3 programmable and 1 committed to output the
armature current signal .
A OP1/2/3 Programmable output specification.
12 bit plus sign resolution (2.5mV steps).
Short circuit protection to 0 V. (Protection is only
available for any one output. More than 1 OP
shorted may damage the unit).
Output current + /-5mA maximum.
Output range 0 to + /-11.300 V. (10 V normally
represents 100%).
13.4.1 AN ALO G OUTPUTS / A OP4 Iarm
output rectify enable PIN 250
13.4.2 AN ALOG OUTPUTS / A OP1/2/3/4 SETUP
There are 3 menus, 1 for each analogue output.
This list shows A OP1
The signal to be output is obtained from the
internal system using the GET FROM window.
The next process is a signed scaling divider
followed by an offset, which may be added or
subtracted. The output mode may be selected as
either rectified or bi-polar, prior to being placed on
the terminal as a linear voltage signal.
AOP1
GET FRO M
T 1 0
PIN 252
Offset
PIN 253
Rect/Bipolar
PIN 251
PIN 159
OP monitor
ANALO G OUTPUTS 3
250)Iarm OP RECTIFY
250)Iarm OP RECTIFY
DIS ABLED
PARA METER RA NGE DEF AULT PIN
Iarm OP RECTIFY ENABLED or DIS ABLED DIS ABLED 250
Sets Iarm output (T29) to be
either bi -polar or rectified.