192 CONFIGURA TION
13.9.3 SO FTW ARE TERMIN ALS / Anded start PIN 307
307)A NDED ST ART is normally used by a
serial link to control the drive. The local
hard ware terminal in the LO W position
will defeat the serial link.
The serial link in the OFF position will
defeat the local hardware terminal.
13.9.4 SOFT W ARE TERMIN ALS / Internal run input PIN 30 8
The RUN command normally comes from the default RUN terminal (T31) and wi ll show the state of T31.
How ever this terminal may be used as a programmable terminal in the event of a shortage of digital inputs. In
this case 308)INTERNAL RUN IP must be disconnected from the RUN terminal and set HIGH to allo w the
drive to run.
From ST ART T33
From ANDED
ST ART PIN 307
HIGH or LOW
To internal
system
SOFTW ARE TERMIN ALS 3
307)A NDED ST ART
307)A NDED J OG
HIGH
PARA METER RA NGE DEFAULT PIN
ANDED ST ART HIGH or LO W HIGH 307
Sets a logic input to an internal
AND gate to control START.
SOFTW ARE TERMIN ALS 3
308)INTERN AL RUN IP
308)INTERN AL RUN IP
LOW
PARA METER RA NGE DEFAULT PIN
INTERN AL RUN IP HIGH or LO W LO W 308
Used to set RUN mode if the
RUN terminal is reprogrammed.