212 Installation
14.8 Line reactors
Only use CS A/UL certified line reactors for installations complying with CS A/UL codes. These line reactors
are not certified. Refer to supplier for certified alternatives.
Output power
At
500 V
Max continuous
Current (AMPS)
Model
PL 2Q
PLX 4Q
At
4 60V
K w HP
HP
Input
A C
Output
DC
Line reactor
Type
PL/X5
5 7 7.5 10 12
LR48
PL/X10
10 13 1 5 20 24
LR48
PL/X15
15 20 2 0 30 36
LR48
PL/X20
20 27 3 0 40 51
LR48
PL/X30
30 40 4 0 60 72
LR120
PL/X40
40 53 6 0 80 99
LR120
PL/X50
50 67 7 5 100 123
LR120
PL/X65
65 90 1 00 124 155
LR270
PL/X85
85 115 125 1 64 205
LR270
PL/X115
115 1 55 160 216 270
LR270
PL/X145
145 1 90 200 270 330
LR330
PL/X185
185 2 50 270 350 430
LR430
PL/X225
225 3 00 330 435 530
LR530
PL 265
265 3 60 400 520 630
LR630
Please also refer to Part 3 PL/X 275-980 for extra details of frame 4 and 5 high power drives.
To obtain line reactor dimensions
Please refer to w w w .sprint-electric.com