CHA NGE PARA METERS 75
6.2.10 RUN M ODE RA MPS / Ramp automatic preset PIN 29
The SYSTEM RESET produces a logic pulse (5mS) each time the MAIN C ON T A CTOR is energised.
See 6.2.1 RUN M ODE RA MPS / Block diagram including JOG.
6.2.11 RUN M ODE RA MPS / Ramp external preset PIN 30
A logic high enables the preset. It is also OR’d with 29)RA MP AU TO PRESET if this is enabled.
See 6.2.1 RUN M ODE RA MPS / Block diagram including JOG.
6.2.12 RUN M ODE RA MPS / Ramp preset value PIN 31
6.2.1 3 RUN M ODE RA MPS / Ramp S-profile % PIN 32
Note. A value of 0.00% will produce a linear ramp. The ramp time will be become longer when the S shape
% is increased. This is because the rate of change in the remaining linear portion is maintained.
6.2.14 RUN M ODE RA MPS / Ramp hold enable PIN 33
Note the 30)RAMP EX T PRESET function will overide the 33)RA MP HOLD function.
RUN MODE RAMPS 3
29)RA MP AU TO PRESET
29)RA MP AU TO PRESET
ENABLED
PARA METER RANGE DEFAULT PIN
RA MP AUTO PRESET EN ABLED or DIS ABLED EN ABLED 29
When enabled, the system
reset also presets the ramp.
RUN MODE RAMPS 3
30)RA MP EX T PRESET
30)RA MP EX T PRESET
DISABLED
PARA METER RANGE DEFAULT PIN
RA MP EXT PRESET EN ABLED or DIS ABLED DISABLED 30
When enabled the ramp is held
in preset mode.
RUN MODE RAMPS 3
31)RA MP PRESET V ALUE
31)RA MP PRESET V ALUE
0.00%
PARA METER RANGE DEFAULT PIN
RA MP PRESET V ALUE + /-30 0.00 % 0.00% 31
When the ramp is preset this is
the value it goes to.
RUN MODE RAMPS 3
32)RA MP S-PROFILE %
32)RA MP S-PROFILE %
2.50%
PARA METER RANGE DEFAULT PIN
RA MP S-PROFILE % 0.00 to 100.00 % 2.50% 32
This value sets the % of the S
ramp shape at each end
RUN MODE RAMPS 3
33)RA MP HOLD
33)RA MP HOLD
DIS ABLED
PARA METER RAN GE DEFAULT PIN
RAMP HOLD ENABLED or DIS ABLED DIS ABLED 33
When EN ABLED the ramp is
held at the present value.