80 CHA NGE PARA METERS
6.3.5 JOG CRA WL SLA CK / Jog mode select PIN 42
The factory default for JO G MO DE SELECT is an external connection to T19.
Operating
function
JO G MO DE
SELEC T
T19 IP level
ST ART T3 3
IP level
JOG T32
IP level
Ramp input
Total value
Applied ramp
time
Contactor
state
Stopped low lo w low reference Stop ramp OFF
Stopped high lo w lo w reference Stop ramp OFF
Running low high low reference Run mode ramp ON
Slack 1 takeup low high high ref + slack 1 Jog/slack ramp ON
Slack 2 takeup high high high ref + slack 2 Jog/slack ramp ON
Jog speed 1 lo w low high Jog speed 1 Jog/slack ramp ON
Jog speed 2 high lo w high Jog speed 2 Jog/slack ramp ON
Crawl high high low Crawl speed Run mode ramp ON
6.3.6 J OG CRA WL SLA CK / Jog/Slack ramp PIN 43
Note. The ramp time is the same for up/do wn and forw ard/reverse. It is the time taken to reach 100 % speed.
JO G CRA WL SLA CK 3
42)JO G MODE SELECT
42)JO G MODE SELECT
LO W
PARA METER RANGE DEFAULT PIN
JO G MODE SELECT LOW or HIGH LOW 42
Combines with the J OG/ST ART
inputs for jog/cra wl/slack mode
RR
JO G CRA WL SLA CK 3
43)JO G/SLA CK RA MP
43)JO G/SLA CK RA MP
1.0 SECS
PARA METER RANGE DEFAULT PIN
JO G/SLACK RA MP 0.1 to 600 seconds 1.00 secs 43
Jog/slack mode has this ramp
time which overides any others
RR