EasyManua.ls Logo

Bardac PLX - Page 80

Default Icon
235 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
80 CHA NGE PARA METERS
6.3.5 JOG CRA WL SLA CK / Jog mode select PIN 42
The factory default for JO G MO DE SELECT is an external connection to T19.
Operating
function
JO G MO DE
SELEC T
T19 IP level
ST ART T3 3
IP level
JOG T32
IP level
Ramp input
Total value
Applied ramp
time
Contactor
state
Stopped low lo w low reference Stop ramp OFF
Stopped high lo w lo w reference Stop ramp OFF
Running low high low reference Run mode ramp ON
Slack 1 takeup low high high ref + slack 1 Jog/slack ramp ON
Slack 2 takeup high high high ref + slack 2 Jog/slack ramp ON
Jog speed 1 lo w low high Jog speed 1 Jog/slack ramp ON
Jog speed 2 high lo w high Jog speed 2 Jog/slack ramp ON
Crawl high high low Crawl speed Run mode ramp ON
6.3.6 J OG CRA WL SLA CK / Jog/Slack ramp PIN 43
Note. The ramp time is the same for up/do wn and forw ard/reverse. It is the time taken to reach 100 % speed.
JO G CRA WL SLA CK 3
42)JO G MODE SELECT
42)JO G MODE SELECT
LO W
PARA METER RANGE DEFAULT PIN
JO G MODE SELECT LOW or HIGH LOW 42
Combines with the J OG/ST ART
inputs for jog/cra wl/slack mode
RR
JO G CRA WL SLA CK 3
43)JO G/SLA CK RA MP
43)JO G/SLA CK RA MP
1.0 SECS
PARA METER RANGE DEFAULT PIN
JO G/SLACK RA MP 0.1 to 600 seconds 1.00 secs 43
Jog/slack mode has this ramp
time which overides any others
RR

Table of Contents