CHA NGE PARA METERS 79
6.3.2 JOG CRA WL SLA CK / Jog speed 1 / 2 PINs 37 / 38
6.3.3 J OG CRA WL SLA CK / Slack speed 1 / 2 PINs 39 / 40
6.3.4 JOG CRA WL SLA CK / Cra wl speed PIN 41
JO G CRA WL SLA CK 3
37)JO G SPEED 1
37)JO G SPEED 1
5.00%
PARA METER RANGE DEFAULT PIN
JO G SPEED 1 + /-100.0 0% 5.00% 37
Sets the value of jog speed 1
Usually used for forward jog.
R R
JO G CRA WL SLA CK 3
38)JO G SPEED 2
38)JO G SPEED 2
-5.00%
PARA METER RANGE DEFAULT PIN
JO G SPEED 2 + /-100.0 0% -5.00 % 38
Sets the value of jog speed 2
Usually used for reverse jog.
RR
JO G CRA WL SLA CK 3
40)SLA CK SPEED 2
40)SLA CK SPEED 2
-5.00%
PARA METER RANGE DEFAULT PIN
SLA CK SPEED 2 + /-100.00% -5.00% 40
Sets the value of slack speed 2
Usually used for reverse slack.
RR
JO G CRA WL SLA CK 3
39)SLA CK SPEED 1
39)SLA CK SPEED 1
5.00%
PARA METER RANGE DEFAULT PIN
SLA CK SPEED 1 + /-100.00% 5.00 % 39
Sets the value of slack speed 1
Usually used for forward slack.
RR
JO G CRA WL SLA CK 3
41)CRA WL SPEED
41)CRA WL SPEED
10.00%
PARA METER RANGE DEFAULT PIN
CRA WL SPEED + /-100.00% 10.00% 41
Sets the value of cra wl speed.
RR