Measuring system MAK TIGER 3003
19
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
5.2 Piping
The measurement system MAK TIGER has an inlet and an outlet with DN 80
(optional DN 100) connections.
The remaining equipment is furnished by the superstructure builder for the
tank trucks. These additional superstructures have a significant influence on
the performance of the milk collection truck.
Please note:
If possible, avoid any:
changes in cross-section
abrupt bows
rectangular pipe outlets
T-pieces
inwardly protruding welding seams
rough inside walls of pipes
fittings protruding into the pipe
everything that swirls the flow
everything that impairs the flow
Particularly on the suction side, the piping system including the sampler and
the flowmeter has to be carried out continuously in min. 3” to prevent pressure
drops.
To maximize the transfer pump performance, the plumbing for the tank outlets,
the tap and the transfer pump piping should have a diameter of at least DN
80. The transfer pump valve used by BARTEC BENKE corresponds to DN 80
(optional DN 100) in accordance with DIN 11850.
For the construction of the measurement system, it is of particular importance
that the components of the measurement system are installed in a tension-
free way. One possibility is to uncouple the pipework at suitable places by
means of hose connections. If the components of the measurement system
are fastened to different reference systems, these components have to be
mounted by means of flexible fastening elements (e.g. rubber dampers).