Measuring system MAK TIGER 3003
21
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
5.4 Technical data
Measuring system-specific data
Operating voltage
DC 24 V (9 - 36V) on-board power supply (load dump fixed,
stabilized)
Emergency operation
On-board power supply 24 V (valves)
Compressed air
Ejector
5,6 bar (maintenance unit)
Valve terminal
6 bar (maintenance unit)
Compressed air / level
4 bar filter 0,01 µ
Air consumption of ejector
approx. 500 nl/min @ 5,6 bar
Suction power
typ. 1300 l/min during good intake conditions,
max. 2000 l/min during pumping
Drive
Hydraulic motor 23,7 cm³
Flow rate of hydraulic oil
about 40 l/min @ 200 bar
Speed
about 1500 revs/min
Hydraulic connection
Forward side ≥ 16 mm , Return side ≥ 28 mm
Hydraulic fluid
≥60 l with oil cooler, HVLP DIN51524 T3
Connections level container
DIN 80 (optional DN 100) Clamp for pumping and sucking
Precision
≤ 0,5 %
Lowest intake quantity
100 l with 3“ MID, optional 50 l with 2,5“ MID
CIP
yes;
max. 85 °C @ 2 bar
Mechanical data
Material of milk conduit
V
2
A; PTFE; PEEK, POM
Dimensions
See dimensional drawing
Weight
approx. 230 kg
Ambient conditions
Operating temperature
0 … + 85 °C medium; - 20 … + 50 °C electronics
Storage temperature
- 20 … + 60 °C (without fluid)
Protection type
IP 65