ULTRASAMPLER® sample collection system
157
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
26.2.4 Terminal connection plan
A (2x)
B (2x)
S (2x)
+ (2x)
- (2x)
P-NET A fieldbus
P-NET B fieldbus
P-NET S fieldbus
+24 V supply from cut-in unit
0 V supply from cut-in unit
P-NET ring
P-NET ring
P-NET ring
P-NET ring
P-NET ring
Frame ground for cable shielding
RS 232 C interface
RS 232 C interface
RS 232 C interface
RS 232 C interface
RS 232 C interface
Inactive
Inactive
Inactive
Inactive
Inactive
UB sensor (+24 V for FLM supply)
UB sensor (GND for FLM supply)
FLM fill level (0…2.5 V)
FLM flow rate (4…20 mA)
GND reference potential for fill level + flow rate
pk/ gy
Shield
ye
vt
bn/bk
Flow level meter (FLM)
Type 6826
cf. 1)
6
7
8
9
10
11
12
13
14
15
Digital output OUT 1
Digital output OUT 2
Digital output OUT 3
Digital output OUT 4
Reference ground for OUT 1-4
Digital output OUT 5
Digital output OUT 6
Digital output OUT 7
Digital output OUT 8
Reference ground for OUT 5-8
As required
As required
As required
As required
As required
As required
As required
As required
As required
As required
Sampler motor for individual sample, phase A
Sampler motor for individual sample, phase B
Sampler motor for individual sample, phase C
Sampler motor for individual sample, phase D
Sampler motor for single
sample
UB sensor (+12 V for probe)
Frequency input 1 (milk temperature, cf. 3)
Frequency input 2 (milk sensor, cf. 3)
UB sensor (GND for probe)
UB sensor (+12 V for probe)
Frequency input 3 (sampling cabinet temperature, cf.
3)
UB sensor (GND for probe)
25
26
27
28
29
30
31
32
33
34
+24 V on-board power supply, auxiliary supply for
sensor system
Digital input IN 1
Digital input IN 2
Digital input IN 3
Digital input IN 4
Digital input IN 5
Digital input IN 6, bottle in position, cf. 2)
Digital input IN 7, star in position, cf. 2)
Digital input IN 8, bottle down, cf. 2)
0 V on-board power supply, reference ground for
IN 1-8
As required
As required
As required
As required
As required
As required
Bottle drive
P-Star (terminal 49)
Bottle drive
As required
Sampler motor for tank sample, phase A
Sampler motor for tank sample, phase B
Sampler motor for tank sample, phase C
Sampler motor for tank sample, phase D
Sampler motor for whole
tank sample