Measuring system MAK E-TIGER 3003
66
Measuring System MAK TIGER 3003 Service manual, SA 131128, 10.03.2020
6.10 Terminal assignments for Ultra-
sampler controller
Termi-
nal
Signal designation
Colour
connected to
A (2x)
B (2x)
S (2x)
+ (2x)
- (2x)
P NET A field bus
P NET B field bus
P NET S field bus
+24 V supply from cut-in unit
0 V supply from cut-in unit
yl
gn
br
rd
bl
P NET ring
P NET ring
P NET ring
P NET ring
P NET ring
Frame ground for cable shielding
Cable shielding
RxD
TxD
CTS
RTS
GND
RS 232 C interface
RS 232 C interface
RS 232 C interface
RS 232 C interface
RS 232 C interface
Inactive
Inactive
Inactive
Inactive
Inactive
1
2
3
4
5
UB sensor (+24 V for FLM supply)
UB sensor (GND for FLM supply)
FLM level (0-2.5 V)
FLM flow rate (4-20 mA)
GND reference potential for fill level + flow rate
pi/gr
Shield
yl
vi
br/bk
Flow level meter (FLM)
Type 6826
cf. 1)
6
7
8
9
10
11
12
13
14
15
Digital output OUT 1
Digital output OUT 2
Digital output OUT 3
Digital output OUT 4
Reference ground for OUT 1-4
Digital output OUT 5
Digital output OUT 6
Digital output OUT 7
Digital output OUT 8
Reference ground for OUT 5-8
-X5:1
-X5:2
-X5:13
-X5:8
As required
As required
As required
As required
As required
As required
As required
As required
As required
As required
16
17
18
19
Sampler motor for individual sample, phase A
Sampler motor for individual sample, phase B
Sampler motor for individual sample, phase C
Sampler motor for individual sample, phase D
bl
br/wt
gn/yl
gr/pi
Sampler motor for indi-
vidual sample
20
21
22
24
UB sensor (+12 V for probe)
Frequency input 1 (milk temperature, cf. 3)
Frequency input 2 (milk sensor, cf. 3)
UB sensor (GND for probe)
Inactive
20
23
24
UB sensor (+12 V for probe)
Frequency input 3 (sample compartment temperature, cf.
3)
UB sensor (GND for probe)
Inactive
25
26
27
28
29
30
31
32
33
34
+24 V on-board power supply, auxiliary supply for sensor
system
Digital input IN 1
Digital input IN 2
Digital input IN 3
Digital input IN 4
Digital input IN 5
Digital input IN 6, (bottle in position)
Digital input IN 7, (star in position)
Digital input IN 8, (bottle down)
0 V on-board power supply, reference ground for IN 1-8
-2A2:gr
-X5:5
-X5:4
1B1:14
-X5:11
bl
Wire jumper
pi/wt
-2A2:bl
As required
As required
As required
As required
As required
As required
Bottle drive
P-Star (Terminal 49)
Bottle drive
As required