In Motive, change the layout to Configuration preset. From the Layout menu, choose1.
Configuration.
In the Synchronization window, under Synchronization, click Custom Synchronization from the drop-2.
down menu.
Under the Sync Input heading, set the Source field to Reserved.1.
Set the Synchronization offset to 5000.2.
Click Apply3.
Note: The Input Monitor section can be used to immediately check if the TimeKeeper is
connected correctly to the eSync and Motive. In the Reserved field of the Input Monitor
section, there should be a value of around 100 Hz (or close to this number). This mean
Motive is receiving the TimeKeeper sync signal. If this number is not in the range of
99.998 - 100.004 Hz (or close) there may be a configuration issue with the TimeKeeper,
and you should report the issue to a BTE to be resolved.
Note: If you experience Tracking issues after configuring these settings, reset Motive Settings from the
BlackTrax GUI. If your issue is not resolved, please contact BlackTrax support for further assistance.