Hybrid Power Supply Unit (HPSU)
Hybrid Power Supply Unit (HPSU)
Size and Weight
Width: 1.35 cm (0.5")
Height: 0.45 cm (0.2")
Depth: 1.1 cm (0.4")
Power Run Time
High: 1:00
Med: 2:45
Low: 3:15
Notes
Most applications (comparable to the previous PSU) use Medium, depending on the size of the1.
venue and how far the sensors are. You may try out low or high to conserve power or boost the IR.
A USB port is available where you can use to charge an external Beacon. 2.
An External Beacon can be charged approximately 90% if the HPSU is fully charged, and the
Beacon Battery is completely out of charge. This assumes no Stringers are attached to the
Beacon.
The HPSU can also be used to extend the life of a Beacon Battery if it is required to run past
its normal usage time. A Beacon with 1 Stringer has approximately 7.5 hours of additional
usage time. Beacons with either 2 or 3 Stringers attached have approximately 1 hour of
additional usage time.
Changing Internal Batteries in the HPSU
Attention: Please use an anti-static mat while being grounded.
Tool Required: *1/16 hex bit key.
To add batteries to the second pack