EasyManua.ls Logo

BlackTrax BTSensor - Page 194

Default Icon
298 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
In the Additional Pan-Flip Dimming Time field, specify the number of seconds or use the slider4.
to add extra pan-flip dimming time.
Note: The range of time is limited to 0-3 seconds.
For the changes to take effect, click Apply Changes.5.
Smooth Pickups: This feature turns the fixture On once as a single event per chapter, only when
the Beacon is visible.
BlackTrax checks for motion at the beginning of the chapter.
BlackTrax automatically douses the fixture to 0 if motion is not detected. When motion is
seen, the fixture fades in to console control over the fade time specified once the Trackable
Visible For: time has elapsed (motion must be seen continuously during this time for the fade
to start).
When completed, the Smooth Pickups feature is disabled for the remainder of the chapter.
Smooth Pickups is disabled by default.
To enable and set smooth pickups
In the Chapter widget, select the chapter the fixture is in.1.
In the Center pane, click on the Trackable the fixture is assigned to and click on the Fixture Icon of2.
the fixture to select it.
With the Fixture Icon selected, go to the Fixture Settings widget.3.
Under the Basic Settings section, select the checkbox Smooth Pickups.4.
Click on the Trackable Visible For: scroll box to set the length of time required for a Trackable to be5.
visible and the light to fade in.
Click on the Fade-in time: scroll box to set how long the light fades in.6.
Auto Douse: This feature turns the fixture On only when the Beacon is visible and as an ongoing
event all throughout the course of the chapter.
If all LEDs of the patched Beacon becomes hidden, BlackTrax automatically douses the fixture
to 0 (from console control) after the reaction time is complete.
BlackTrax automatically fades in the fixture when at least one LED is visible and after the
reaction time is complete.
Reaction time is the length of time required for motion to be visible, or to be hidden before
the fade time starts.
To enable and set auto douse
In the Chapter widget, select the chapter the fixture is in.1.
In the Center pane, click on the Trackable the fixture is assigned to and click on the Fixture Icon of2.
the fixture to select it.
With the Fixture Icon selected, go to the Fixture Settings widget.3.
Under the Basic Settings section, select the checkbox Auto Douse.4.
Click on the Reaction Time: scroll box to set the length of hidden or visible time for fade time to5.
start.
Click on the Fade-In Time: scroll box to set how long the light fades in.6.
Click on the Fade-Out Time: scroll box to set how long the light fades out. 7.
Following Sensitivity
Sensitivity determines exactly how a fixture is supposed to follow a Trackable. The prediction algorithms
takes the current BTBeacon and fixture information and makes an informed prediction on where the
Trackable will be next. The BTSystem will then be able to anticipate where the fixture needs to aim to
BlackTrax Wiki
194 of 298
5/14/2019

Table of Contents