Chapter 4 Error Messages
EID-6107 The node failed to restart the TELNET service on the selected
port. Try using another unreserved port that is not being used
within the following ranges:
23, 1001-9999 (with the exception of 1080, 2001-2017, 2361,
3081-3083, 4001-4017, 4022, 4081, 4083, 5000, 5001, 7200,
9100, 9300, 9401).
Refer to the error message text.
EID-6108 That port is already in use. Restart a TELNET session.
EID-6109 A section trace is active on the trunk port. The action cannot be
completed.
Actions such as putting the port in an
incomplete state are not permitted while a
section trace is active.
EID-6110 The maximum number of TARP requests has been reached. You have exceeded the maximum number
of TARP requests.
EID-6111 The card in Slot {0} cannot be removed from the protection
group while its traffic is switched.
Refer to the error message text.
EID-6112 An error occurred while adding a shelf: {0} The shelf ID specified is invalid or already
exists, the equipment does not support
multishelf, the specified shelf position is
out of range, or the specified shelf position
is already in use.
EID-6113 An error occurred while deleting a shelf: {0} One or more of the equipment modules
(provisioned virtual links, provisioned
server trails, provisioned protection groups,
or provisioned DCCs) in the shelf is
currently in use. Delete cards from all the
slots and try again.
EID-6114 The maximum number of supported shelves has already been
provisioned.
Refer to the error message text.
EID-6115 There are bad or duplicate shelf positions.
Valid rack numbers are {0} to {1}.
Valid rack positions are {2} to {3}.
Refer to the error message text.
EID-6116 CTC attempted to access an OCH-Trail connection that has
been destroyed.
Software has prevented an attempt to access
an OCH trail.
EID-6117 CTC attempted to access an OCH-Trail audit that has been
destroyed.
The resource cannot be accessed because it
is released or fully utilized.
WID-6118 The following slots are provisioned but do not have cards
installed:
{0}
CTC will assume they are ITU-T interfaces.
Refer to the warning message text.
EID-6119 The shelves could not be rearranged.
{0}
One of the following conditions is present:
duplicate shelf positions, invalid shelf
positions, or concurrent movement (two
CTC sessions are attempting to rearrange
the shelves at the same time.)
EID-6120 This equipment does not support multishelf. Refer to the error message text.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description

Table of Contents