4-49
Cisco ONS 15454 Troubleshooting Guide, R8.5
November 2009
Chapter 4 Error Messages
EID-6254 SDH mode does not support timing references. Timing reference is not supported by SDH
mode.
EID-6255 Only DS1 interfaces with ESF line types support timing
references.
Refer to the error message text.
EID-6256 sendDoNotUse and sendDoNotUseFF are mutually exclusive. Refer to the error message text.
EID-6257 The termination is already in use. Refer to the error message text.
EID-6258 The side is carrying services or traffic. Refer to the error message text.
EID-6259 A pluggable module on Port 22 remains unmanaged. Refer to the error message text.
EID-6260 You cannot delete this port.
There was a severe architectural error related to the index of the
pluggable trunk port object.
Please contact technical support for assistance.
Refer to the error message text.
EID-6261 This is not a valid VLAN ID. The VLAN database is empty. The user adds a row without a valid VLAN
database loaded.
EID-6263 The equipment requires two slots. The user provisions a double footprint card
in a single slot.
EID-6264 The patchcord is duplicated. Refer to the error message text.
EID-6265 The wavelength is in use by an OCH trail, a virtual link, or an
internal patchcord.
Refer to the error message text.
EID-6266 The card cannot be changed because the port has not been
provisioned.
Refer to the error message text.
EID-6267 Each port can have a maximum of 8 MAC addresses. Refer to the error message text.
EID-6268 This server trail does not have a valid start or end. Refer to the error message text.
EID-6269 The maximum number of server trails is 3743. Refer to the error message text.
EID-6270 A unique server trail ID could not be allocated. Refer to the error message text.
EID-6271 The server trail already exists. Refer to the error message text.
EID-6272 The server trail size must not exceed the port bandwidth. Refer to the error message text.
EID-6273 An OCH Trail circuit is active on the trunk port.
To modify the ITU-T G.709 parameter, the circuit must be out
of service.
Refer to the error message text.
EID-6274 Unable to restore this database:
The software version cannot be obtained from the node. Please
try again.
Refer to the error message text.
EID-6275 You cannot change this parameter.
The port is part of an active circuit.
Certain parameters like Port Rate and
Admin State cannot be changed when the
port is part is part of an active circuit.
Delete all the circuits on the port before
changing admin state of the port.
EID-6276 APC is disabled. APC Correction Skipped. Override cannot be
performed.
Refer to the error message text.
Table 4-1 Error Messages (continued)
Error Warning
ID Error Warning Message Description