Example
To create an sFlow analyzer server named “monitor”:
DGS-3620-28PC:admin#create sflow analyzer_server 1 owner monitor
Command: create sflow analyzer_server 1 owner monitor
Success.
DGS-3620-28PC:admin#
100-5 config sflow analyzer_server
Description
This command is used to configure the sFlow analyzer server information. More than one collector
with the same IP address can be specified if the UDP port numbers are unique.
Format
config sflow analyzer_server <value 1-4> {timeout [<sec 1-2000000> | infinite] |
collectoraddress [<ipaddr> | <ipv6addr>] | collectorport <udp_port_number 1-65535> |
maxdatagramsize <value 300-1400>}(1)
Parameters
<value 1-4> - Enter the analyser server ID used here. This value must be between 1 and 4. The
switch supports 4 different analyser servers at the same time. Each sampler or poller can
select a server ID (1, 2, 3, or 4) to send the samples.
timeout - (Optional) Specifies the time (in seconds) remaining before the sample is released and
stops sampling. When the analyzer_server times out, all of the flow_samplers and
counter_pollers associated with this analyzer_server will be deleted. If it is specified as infinite,
the server will never be timeout.
<sec 1-2000000> - Enter the time out value, in seconds, between 1 and 2000000.
infinite - Specifies to never time out.
collectoraddress - (Optional) Specifies the IP address of the server.
<ipaddr> - Enter the IP address of the server. If set to 0, sFlow packets will not be sent to this
server.
<ipv6addr> - Specifies the IPv6 used.
collectorport - (Optional) Specifies the destination port for sending sflow datagrams.
<udp_port_number 1-65535> - Enter the destination port for sending sflow datagrams. The
number is between 1 and 65535.
maxdatagramsize - (Optional) Specifies the maximum number of data bytes that can be packed
in a single sample datagram.
<value 300-1400> - Enter the maximum number of data bytes that can be packed in a single
sample datagram. The values is between 300 and 1400.
Restrictions
Only Administrators and Operators can issue this command.
Example
To configure the sFlow analyzer server information:
DGS-3620-28PC:admin#config sflow analyzer_server 1 collectoraddress 10.90.90.9

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the D-Link xStack DGS-3620 Series and is the answer not in the manual?

D-Link xStack DGS-3620 Series Specifications

General IconGeneral
BrandD-Link
ModelxStack DGS-3620 Series
CategorySwitch
LanguageEnglish

Related product manuals