xStack® DGS-3620 Series Layer 3 Managed Stackable Gigabit Switch CLI Reference Guide
491
Chapter 36
External Alarm
Commands
config external_alarm {unit <unit_id>} channel <value 1-2> message <sentence 1-128>
show external_alarm {unit <unitlist>}
36-1 config external_alarm
Description
This command is used to configure external alarm message for a channel.
The source of alarm is located outside of the switch. They are monitored via pre-defined
connection channels, with each channel representing a specific alarm event. This command allows
the user to define the alarm event associated with each channel.
Format
config external_alarm {unit <unit_id>} channel <value 1-2> message <sentence 1-128>
Parameters
unit - Specifies the unit to display.
<unit_id> - Specifies the switch in the switch stack.
channel - Specifies which channel is selected to configure.
<value 1-2> - Enter the value of the channel number to be used here.
message - Alarm messages to display on console, log and trap.
<sentence 1-128> - Enter up to 128 characters here for the message to be displayed.
Restrictions
Only Administrators, Operators and Power-Users can issue this command.
Example
To configure an alarm message for channel 1 of unit 2:
DGS-3620-28PC:admin# config external_alarm unit 2 channel 1 message External
Alarm: UPS is exhausted!
Command: config external_alarm unit 2 channel 1 message External Alarm: UPS is
exhausted!
Success.
DGS-3620-28PC:admin#