EasyManuals Logo

Datalogic DX8210 User Manual

Datalogic DX8210
300 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #243 background imageLoading...
Page #243 background image
PackTrack™
Reference Manual 231
4. Measure the distance for Y from the trigger (PS line) to the center of the
barcode (edge of the box), and enter that distance in the first box under Y-
Coord (mm).
Your measurements will likely differ from those shown below.
5. Measure the distance for Z from the conveyor bed to the center of the bar-
code, and enter that dist
ance in the first box under Z-Coord (mm).
Your measurements will likely differ from those shown below.
6. Click Calibrate 1. PackTrack data is displayed for the first code.
To make it easier to measure the Y-Coordinate, place a box along the photoelectric
sensor laser line (Trigger). Then the end of the tape measure or ruler can be place
against the edge of the box. See below.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic DX8210 and is the answer not in the manual?

Datalogic DX8210 Specifications

General IconGeneral
BrandDatalogic
ModelDX8210
CategoryBarcode Reader
LanguageEnglish

Related product manuals