4. Measure the distance for Y from the trigger (PS line) to the center of the
barcode (edge of the box), and enter that distance in the first box under Y-
Coord (mm).
Your measurements will likely differ from those shown below.
5. Measure the distance for Z from the conveyor bed to the center of the bar-
code, and enter that dist
ance in the first box under Z-Coord (mm).
Your measurements will likely differ from those shown below.
6. Click Calibrate 1. PackTrack data is displayed for the first code.
To make it easier to measure the Y-Coordinate, place a box along the photoelectric
sensor laser line (Trigger). Then the end of the tape measure or ruler can be place
against the edge of the box. See below.