EasyManua.ls Logo

Datalogic Heron HD3100 - Industrial 2 of 5 Check Character Transmission; Industrial 2 of 5 Length Control

Datalogic Heron HD3100
298 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Enter/Exit Programming Mode Industrial 2 of 5
180 Heron™ HD3130
Industrial 2 of 5 Check Character Transmission
Enables/disables transmission of an Industrial 2 of 5 check character.
Industrial 2 of 5 Check Character Transmission = Disable
Industrial 2 of 5 Check Character Transmission = Enable
DEFAULT
Industrial 2 of 5 Length Control
This feature specifies either variable length decoding or fixed length decoding
for the Industrial 2 of 5 symbology.
Variable Length:
For variable length decoding, a minimum and maximum length
may be set.
Fixed Length:
For fixed length decoding, two different lengths may be set.
DEFAULT
Industrial 2 of 5 Length Control = Variable Length
Industrial 2 of 5 = Fixed Length
$CU2CT00
$CU2CT01
$CU2LC00
$CU2LC01

Table of Contents