References
218 Heron™ HD3130
RS-232 Parameters
RS-232 Only
Baud Rate
Baud rate is the number of bits of data transmitted per second. Set the scan-
ner's baud rate to match the baud rate se
tting of the host device. With an
improper baud rate setting, data may not reach the host correctly.
Stop Bits
The stop bit(s) at the end of each transmitted character marks the end of trans-
mission of one character and prepares the receiving device for the next charac-
ter in the serial data stream. The number of stop bits selected (one or two)
de
pends on the number the receiving terminal is programmed to accommo-
date. Set the number of stop bits to
match host device requirements.
Parity
This feature specifies parity required for sending and receiving data. A parity
check bit is the most significant bit of each ASCII coded character. Select the
parity type according to host device requirements.
Select None when no parity bit
is required.
Select Odd parity and the parity bit value i
s set to 0 or 1, based on data, to
ensure that an odd number of 1 bits are contained in the coded character.
Select Even parity and the par
ity bit value is set to 0 or 1, based on data, to
ensure that an even number of 1 bits are contained in the coded character.
Handshaking Control
The data interface consists of an RS-232 port designed to operate either with
or without the hardware handshaking lines, Request to Send (RTS), and Clear to
Send (CTS). Handshaking Control includes the following options:
RTS — RTS is asserted during trans
missions. CTS is ignored.
RTS/CTS — RTS is asserted during t
ransmissions. CTS gates transmis-
sions.
RTS/XON/XOFF — RTS is asserted during transmissions.
CTS is ignored.
XON and XOFF gate transmissions.
RTS On/CTS — RTS is always asserted. CTS gates transmissions.
RTS/CTS Scan Control — RTS is asserte
d during transmissions. CTS gates
transmissions and controls enable and disable state of scanner.

Table of Contents

Other manuals for Datalogic Heron HD3100

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Datalogic Heron HD3100 and is the answer not in the manual?

Datalogic Heron HD3100 Specifications

General IconGeneral
BrandDatalogic
ModelHeron HD3100
CategoryBarcode Reader
LanguageEnglish

Related product manuals