References
242 Heron™ HD3130
Scanning Active Time
This setting specifies the amount of time that the reader stays in scan ON state
once the state is entered. The range for this setting is from 1 to 255 seconds in
1-second increments.
Follow these instructions to set this feature:
1. Determine the desired setting.
2. Pad the result with leading zeroes to yield three digits. For example: 0 =
0
00, 5 = 005
, 20 = 020, etc.
3. Scan the ENTER/EXIT PROGRAMMING MODE bar code to enter Program-
ming Mode.
4. Scan the bar code: SELECT SCANNING ACTIVE
T
IME SETTING on
page 82
.
5. Scan the appropriate three digits from the keypad in
Appendix D, Keypad
that represent the duration which was determined in the steps above. You
will
hear a two-beep indication after the last character.
NOTE
If you make a mistake before the last character, scan the CANCEL bar
code to
abort and not save the entry string. You can then start again
at the beginning.
6. Scan the ENTER/EXIT PROGRAMMING MODE bar code to exit Programming
Mode.
This completes the procedure. See the table below for examples of how to set
this fe
at
ure.
Table 18. Scanning Active Time Setting Examples
STEP ACTION EXAMPLES
1 Desired Setting
1 Second 90 Sec. (1.5 min.) 180 Sec. (3 min.)
255 Seconds (4.25
min
.)
2 Pad leading zero(es)
001 090 180 255
3 Scan ENTER/EXIT PROGRAMMING MODE
4 Scan SELECT SCANNING ACTIVE TIME SETTING
5
Scan Three Characters From
Appendix D, Keypad
‘0’, ‘0’ and ‘1’ ‘0’, ‘9’ and ‘0’ ‘1’, ‘8’ and ‘0’ ‘2’, ‘5’ and ‘5’
6 Scan ENTER/EXIT PROGRAMMING MODE