DISASSEMBLY AND ASSEMBLY TRANSFER 347
REINSTALLATION
1. Attach BEARING-BRUSH CAM to the left-side bearing on the main unit.
2. Attach BEARING-BRUSH CAM to the right-side shaft on FRAME ASSY-2ND.
3. Insert the right-side shaft on FRAME ASSY-2ND into the right-side bearing on
the main unit, slide FRAME ASSY-2ND to the left, insert the flange of GEAR 27
on FRAME ASSY-2ND as far as possible into the gear of DRIVE ASSY BTR,
and attach FRAME ASSY-2ND.
4. Insert the right-side BEARING-BRUSH CAM on FRAME ASSY-2ND into the
right-side bearing on the main unit, and fasten with an E-ring.
5. Fasten both the left and right sides of FRAME ASSY-2ND to the main unit with
SPRING-2ND.
6. Attach CAM ASSY-2ND. (p.350)
7. Attach PLATE BIAS-2ND ASSY. (p.358)
8. Attach 2ND BTR ASSY. (p.348)
9. Attach CHUTE ASSY-FSR and COVER ASSY-RR 2ND. (p.341)
10. Attach COVER ASSY RH. (p.301)
Figure 4-62. Removal of FRAME ASSY-2ND (2)
C A U T I O N
When performing the following work, firmly hook SPRING-2ND
onto the concave portion on FRAME ASSY-2ND.
Leg_Sec03_147EB
7)-2
9)
9)
8)
[3)]
[1)]