ECI Multi Functional Weighing Controller Operating Manual
Page 151
For skipping the information screen appeared key is
pressed.
6) Coefficient value is entered. For confirming the value entered press key.
For example;
Load Cell Type: is selected as 2.0 mV/V and if the load
cell of 10 kg with the output of 2.0 mV/V is fully loaded, the
screen value will be 10000 for the coefficient=1,562500
Other sample values will be as shown in the following table
πΎππ‘π ππ¦Δ± =
πΈππππ π·πΔπππ(πππ πΓΌππ‘π)
6400