ECI Multi Functional Weighing Controller Operating Manual
Page 281
Examples
14.6.1 Taring
0x06 is written to the Command register for Taring. (Modbus ID:2 was used)
Modbus
ID
Function
Code
Address Data
CRC
Data
When the operation is performed, the same of the data string sent is returned.
14.6.2 Selecting Recipe
0x14 is written to the Command register (Address 0) for Selecting Recipe. Recipe no is written to RegA or
(Address 1). (Modbus ID:1 was used)
Modbus
ID
Function
Code
Start
Address
Register
Number
Byte
Number
Command
Register
Reg B CRC Data
When the operation is performed, the same of the data string sent is returned.