ECI Multi Functional Weighing Controller Operating Manual
Page 193
Scale capacity
It is the maximum weight value determined for the
batching. If the total quantity intended to be batched is
greater than the "Scale Capacity", more than one filling is
made by dividing as multipliers of the Scale Capacity.
It is also used as the limit of the reservoir that is filled.
Thus, no filling with the quantity more than the value
stated in this parameter will be made to the scale.
Auto Shot
The weight value hang after the valve is closed is
calculated automatically. When this parameter is selected
"On"
the error made on the target quantity of the silo is
corrected automatically.
The options are;
1) Off: Error correction is made manually
2) On: Error correction is made automatically.