14.6.3 Start Batching
0x15 is written to the Command register (Address 0) for start Batching. (Modbus ID:1 was used)
Modbus
ID
Function
Code
Address Data
CRC
Data
01
06
00
00
00
15
48
05
When the operation is performed, the same of the data string sent is returned.
14.6.4 Stop Batching
0x16 is written to the Command register (Address 0) to stop Batching. (Modbus ID:1 was used)
Modbus
ID
Function
Code
Address Data
CRC
Data
01
06
00
00
00
16
08
04
When the operation is performed, the same of the data string sent is returned.