ECI Multi Functional Weighing Controller Operating Manual
Page 274
14.5 Examples:
14.5.1 Reading more than one register.
Such that Modbus ID:1, in order to read the data from register no 8 to register no 14
following data array is sent.
Modbus
ID
Function
Code
Start
Address
Register
Number
CRC
Data
01
03
00
08
00
06
44
0A
The response received is as follows.
Modbus
ID
Function
Code
Byte
Numb
er
Screen
Top
Screen
Bottom
Tare
Upper
Tare
Lower
Gross
Upper
Gross
Lower
CRC
Data
01
03
0C
00
00
01
F4
00
00
00
64
00
00
02
58
85
23
Accordingly
Screen Value=0x000001F4=500
Tare Value=0x00000064=100