ECI Multi Functional Weighing Controller Operating Manual
Page 280
13
Restart the device.
20
Select Recipe: It is used for selecting recipe in batching program. Recipe number should be written to
RegA.
Select Product: It is used for selecting product in filling program. Product number should be written to
RegA.
21
Start Batching: It is used for start batching in batching program.
Start Filling: It is used for start batching in filling program.
22
Start Batching: It is used for stop batching in batching program.
Start Filling: It is used for stop batching in filling program.
128*
Relay 1 Minimum: It is used for setting the minimum value of the 1.relay of the relay card inserted to
Slot 4 in the indication program.
129*
Relay 1 Maximum: It is used for setting the maximum value of the 1.relay of the relay card inserted to
Slot 4 in the indication program.
130*
Relay 2 Minimum: It is used for setting the minimum value of the 2.relay of the relay card inserted to
Slot 4 in the indication program.
131*
Relay 2 Maximum: It is used for setting the maximum value of the 2.relay of the relay card inserted to
Slot 4 in the indication program.
*When the device is restarted or any parameter is changed from the menus, these values return to their value
displayed in the menu.