16) When the discharge input is detected, it is waited for the discharge delay period. (1.5 sec)
17) The discharge output is activated
18) When the weight value <(Tare-Zero Stripe), it is waited for the closing delay. (500ms)
19) The discharge become passive.
20) Stagnancy is waited.
21) If the number of batches is finished, then the operation is finalized.
22) If the number of batches is not finished, Ready input is waited.
23) It is repeated from step 2.
Note:
If, during the operation, any stop entry is observed or stop key is pressed, then the batching operation is terminated.
If there is no change about 10 scale intervals during the fast or slow filling periods, silo time lapse error is given.