2) Accuracy: Net weight information is sent continuously during the batching operation. (Baudrate
is 9600bps)The format of the data string sent is same as the Speed mode
3) Detail: The information is sent in detail after the batching operation is over. (Baudrate is
9600bps).The format of the data string sent is as follows.
Meter TAB
Silo
Name
TAB Silo Weight TAB Total TAB Date TAB Time CR
2 Chr 9 Silo3 Chr 9 300 Chr 9 1200 Chr 9 16.04.2013 Chr 9 08:50:19 CR
Meter
Total number of Batching Resets when the recipe is changed or the device is
restarted.
Silo No
Number of the last silo from which good was taken
Silo Weight
Quantity of the goods taken from the last silo
Total
Last batching amount
Date
Last batching date
Time
Last batching time