ECI Multi Functional Weighing Controller Operating Manual
Page 78
The format of the data recorded in filling program is as follows.
USB recording mode "Weight"
Net
CR
1000 CR
USB recording mode "Detail"
Meter
TAB
Total
TAB
Tare
TAB
Gross
TAB
Date
TAB
Time
CR
1 Chr 9 1000 Chr 9 100 Chr 9 1100 Chr 9 12/02/2013 Chr 9 09:52:23 CR
Meter
It is the batching number. Resets when the recipe is changed or the device is
turned on.
Total
The amount of goods batched
Tare
It is the tare value received at the beginning of the filling when the Automatic
Tare "On" is selected
Gross
Sum of the total and tare value
Date
Date data in Day.Month.Year format.
Time
Time data in Hour.Minute.Second format.