Service Manual_AVA1_ENG-20220922_I 87
DM3&DM4: Film
Action Check > DM3&DM4: Film >
Low speed operation check of the Film Wind Up Motor
(DM3)/Ribbon Film Supply Motor
- Low: Forward Overview Low
speed operation check of the Film Wind Up Motor
(DM3)/ Ribbon
Film Supply Motor (DM4) (feed direction)
To operate the Film Wind Up Motor (DM3) and Ribbon Film
Supply Motor (DM4) for the
specified period of time (1 to 20
seconds) to the feed direction.
Select the item, and then press SET key.
Because the printer becomes operation failure, do not press the
SET key to stop during
operation. If it has been stopped, turn
The motor control for the primary transfer is performed.
Low speed operation check of the Film Wind Up Motor
(DM3)/Ribbon Film Supply Motor
(DM4) (reverse direction)
To operate the Film Wind Up Motor (DM3) and Ribbon Film
Supply Motor (DM4) for the
specified period of time (1 to 20
seconds) to the reverse direction.
Select the item, and then press SET key.
Because the printer becomes operation failure, do not press the
SET key to stop during
operation. If it has been stopped, turn
The motor control for the primary transfer is performed.
:
High speed operation check of the Film Wind Up Motor
(DM3)/Ribbon Film Supply Motor
(DM4) (feed direction)
To operate the Film Wind Up Motor (DM3) and Ribbon Film
Supply Motor (DM4) for the
specified period of time (1 to 20
seconds) to the feed direction.
Select the item, and then press SET key.
Because the printer becomes operation failure, do not press the
SET key to stop during
operation. If it has been stopped, turn
The motor control for the normal feed is performed.
High speed operation check of the Film Wind Up Motor
(DM3)/Ribbon Film Supply Motor
(DM4) (reverse direction)
Low speed operation check of the Film Wind Up Motor
(DM3)/Ribbon Film Supply Motor
(DM4) (reverse direction)
Select the item, and then press SET key.
Because the printer becomes operation failure, do not press the
SET key to stop during
operation. If it has been stopped, turn
The motor control for the normal feed is performed.