Setup
360 FTBx-88000 Series
Path OAM
Continuous check box when selected (default) enables the
continuous delay measurement generation.
Count allows entering the quantity of 2DMM multi-block messages to
be transmitted when not in Continuous mode: 1 to 1000 (default
is 10).
Connectivity Verification
CV Function check box when selected (cleared by default) allows
generating and monitoring CV messages once the test is started.
Period allows entering the transmission period of the CV multi-block
message: 1 s, 10 s (default), or 1 min.
SAPI (Source Access Point Identifier) allows setting the generated SAPI
message (EXFO SAPI by default) and the expected SAPI message
(EXFO SAPI by default) when the Expected check box is selected.
A maximum of 16 characters is allowed.
DAPI (Destination Access Point Identifier) allows setting the generated
DAPI message (EXFO DAPI by default) and the expected DAPI
message (EXFO DAPI by default) when the Expected check box is
selected. A maximum of 16 characters is allowed.
Expected check box when selected (cleared by default) allows setting
the expected SAPI and DAPI messages. When enabled, a mismatch
detection is performed between the generated and expected
messages.