EasyManua.ls Logo

EXFO FTBx-88260 - Streams - Frame Loss; Out-Of-Sequence; Streams - Jitter

EXFO FTBx-88260
1071 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Test Results
536 FTBx-88000 Series
Streams - Frame Loss / Out-of-Sequence
Streams - Frame Loss / Out-of-Sequence
From the Test menu, tap Results, Streams, and the Frame Loss /
Out-Of-Sequence tab.
Note: For Dual Port topology select the port to be displayed.
Stream indicates the stream identification number.
Thresholds button allows setting the pass/fail thresholds (refer to QoS
Metrics on page 430).
Frame Loss: See QoS Metrics on page 907.
Out-Of-Sequence: See QoS Metrics on page 907.
Streams - Jitter
From the Test menu, tap Results, Streams, and the Jitter tab.
Note: For Dual Port topology select the port to be displayed.
Stream: Indicates the stream identification number.
Jitter is measured for each stream on all valid frames (in-sequence
frames, valid Jitter tag, and no FCS error) received. Current, Average,
Minimum, Maximum, and Estimate delay values are reported.
Note: For the Current value, Not measurable is displayed when no delay has
been measured in the last second.
Thresholds button allows setting the pass/fail thresholds (refer to QoS
Metrics on page 430).

Table of Contents

Related product manuals